SyneRAID™-1600U3R
Dual Host Channel Clustering

U3WSCSI/160MBs-to-UDMA/100/133 (Dual Host Channel Clustering) : 3U 19" Rackmount RAID subsystem with Intel i80303 64bit RISC processor controller, 128MB Cache memory, 16 x hot swappable disk canister, hot swappable load sharing redundant power supplies, one RS232 and one 3ft SCSI Cables. Includes GUI RAID Management Software for Windows, Linux & Solaris

SyneRAID-1600FCRC

(3U Rack Copper HSSDC2)

FC-AL/200MBs-to-UDMA/100/133 (SAN Ready): 19" 4U Rack Fiber Channel 2/Gbit Dual Loop with Intel i80303 processor, 128MB Cache Memory, 16 x Hot-Swappable Hard Drives, Hot-Swappable Load Sharing 300watts x 3 Redundant Power Supplies, one RS232 cable and Manual. (optional RAID Management Software) + Fiber Cables Sold Separately

SyneRAID-1600FCRO

(3U Rack Optical LC)

FC/200MBs-to-UDMA/100/133 (SAN Ready): 3U 19" Rackmount RAID subsystem with Intel i80303 64bit RISC processor controller, 128MB Cache memory, support Dual FC-AL loop, 2Gbit/sec per loops, 16 x hot swappable disk canister, hot swappable load sharing redundant power supplies , one RS232 cable and Manual. Fiber Cables Sold Separately

SyneRAID-1600BU3R

(4U Rack)

U3WSCSI/160MBs-to-UDMA/100/133 (Dual Host Channel Clustering) : 4U 19" Rackmount RAID subsystem with Intel i80303 64bit RISC processor controller, 128MB Cache memory, 16 x hot swappable disk canister, hot swappable load sharing redundant power supplies, one RS232 and one 3ft SCSI Cables. Includes GUI RAID Management Software for Windows, Linux & Solaris

SyneRAID-1600SCI

(3U Rack SCSI)

U3WSCSI/160MBs-to-UDMA/100/133 (Dual Host Channel Clustering) : 3U 19" Rackmount RAID subsystem with Intel i80303 64bit RISC processor controller, 128MB Cache memory, 16 x hot swappable disk canister, hot swappable load sharing redundant power supplies, one RS232 and one 3ft SCSI Cables. Includes GUI RAID Management Software for Windows, Linux & Solaris

SyneRAID-1600FCI

(3U Rack Fibre Copper HSSDC2)

FC-AL/200MBs-to-UDMA/100/133 (SAN Ready): 19" 3U Rack Fiber Channel 2/Gbit Dual Loop with Intel i80303 processor, 128MB Cache Memory, 16 x Hot-Swappable Hard Drives, Hot-Swappable Load Sharing 300watts x 3 Redundant Power Supplies, one RS232 cable and Manual. (optional RAID Management Software) + Fiber Cables Sold Separately

SyneRAID-1600FOI

(3U Rack Fibre Optical LC)

FC/200MBs-to-UDMA/100/133 (SAN Ready): 3U 19" Rackmount RAID subsystem with Intel i80303 64bit RISC processor controller, 128MB Cache memory, support Dual FC-AL loop, 2Gbit/sec per loops, 16 x hot swappable disk canister, hot swappable load sharing redundant power supplies , one RS232 cable and Manual. Fiber Cables Sold Separately

SyneRAID-1600SSA

(3U Rack SCSI)

U3WSCSI/160MBs-to-SATA (Dual Host Channel Clustering) : 3U 19" Rackmount RAID subsystem with Intel i80321 64bit RISC processor controller, 128MB Cache memory, 16 x hot swappable disk canister, hot swappable load sharing redundant power supplies, one RS232 and one 3ft SCSI Cables. Includes GUI RAID Management Software for Windows, Linux & Solaris

SyneRAID-1600FCSA

(3U Rack Fibre Copper HSSDC2)

FC-AL/200MBs-to-SATA (SAN Ready): 19" 3U Rack Fiber Channel 2/Gbit Dual Loop with Intel i80321 processor, 128MB Cache Memory, 16 x Hot-Swappable Hard Drives, Hot-Swappable Load Sharing 300watts x 3 Redundant Power Supplies, one RS232 cable and Manual. (optional RAID Management Software) + Fiber Cables Sold Separately

SyneRAID-1600FOSA

(3U Rack Fibre Optical LC)

FC/200MBs-to-SATA (SAN Ready): 3U 19" Rackmount RAID subsystem with Intel i80321 64bit RISC processor controller, 128MB Cache memory, support Dual FC-AL loop, 2Gbit/sec per loops, 16 x hot swappable disk canister, hot swappable load sharing redundant power supplies , one RS232 cable and Manual. Fiber Cables Sold Separately

 

SyneSCA™-U3LP

U3WSCSI/LVD/160MBs Single Channel 64bit-PCI SCSI Adapter w/LSI Symbios 53C1000R High Performance Chipset. Compatible with NT4, Win2000, XP, SCO UNIX, UnixWare, Sun Solaris OS, LINUX, and others.

 

SyneFCA™-2GHC



SyneFCA™-2GDB

 

 

64bit PCI 2GB Fibre Channel Low Profile, Copper Type w/ HSSDC and DB9 Connector. Built-in Qlogic ISP2310 RISC Processor, 400Mbytes/sec Fibre Channel Transfer Rate in full Duplex Mode, FC-AL Private & Public Loop, Point-to-Point, Switched Fabric, FL-Port, F-Port for Fabric Log-in. Concurrent SCSI, IP, Virtual Interface (VI) Protocol and FC Tape Support, Class 2 and 3 Fibre Channel Service, BIOS Support (Local & Fabric)

 

SyneRAID™-1600 3U 16-bay Rack series feature the 2Gbits FC-AL or U3WSCSI/160MBs high performance host interface. The unit is equipped with cost-effective IDE drives offering one of the most powerful RAID subsystem solutions on the market today.

SyneRAIDT-1600 is a fully modular RAID Subsystem with cable-less design and total hot swappability. The unique features of SyneRAIDT-1600 can secure the best system management for high reliability, performance and maintenance.

SyneRAID™-1600 series are furnished with ergonomics in mind, are user friendly and carry sixteen hot-swappable hard drives in rackmount or tower format with a very compact 3U housing. The redundant N+1 power supply can be easily installed or hot-swapped effortlessly to secure opimal system reliability. The SyneRAID™-1600 series meets the demand for over two Terabyte capacities in just a 3U enclosure and delivers the ultimate performance with flexible RAID controller for 2Gb Fibre channel or Ultra 160 SCSI.

 

  • High-Performance Intel i80303 64-bit RISC microprocessor.

  • 2GB Fibre Channel or U3WSCSI/160MBs SCSI architecture offering very high-speed data access.

  • Up to 512MB cache with tuning options to match your data trends.

  • Module and cable-less design enhance system reliability and stability.

  • Redundant, hot-swappable cooling fans ensure system reliability.

  • 750W N+1 Redundant, hot-swappable, load-sharing power supplies with intelligent power spikes reduction and surge management.

  • Supports multiple, global hot spares for complete data protection.

  • Backplane designed for increased reliability and hot-swappability.

  • Intelligent dynamic self-adjusting cooling system for high RPM drives.

  • Proprietary chassis design for enclosure management & status report of all components.

 
Retour à la page du site

  • Host independent controller-based LUN mapping for multiple server environments.

  • Supports Multiple ID, Multiple LUN & Multiple RAID.

  • Supports a wide variety of IDE disk drive capacities.

  • Scales to Terabyte solutions simply on a single RAID controller.

  • Dynamic on-line RAID expansion for instant storage growth without any system downtime.

 

Form Factor:

 

19" 3U Rackmount Chassis

Host Interface: Dual U3WSCSI/160MBs channels or Dual loop 2Gb Fibre channels
System Architecture: OS independent and host transparent, Intel i80303 64-bit RISC Microprocessor, RAID level 0,1, (0+1), 3,5, Multiple RAID and cache memory up to 512MB
Backplane Design: Supported 16-bay UDMA/133 IDE hot-swap disk drives
Hot-Swap Components: Hard Drives, Power Supplies, Cooling Fans
Redundant Components: Hard Drives, Power Supplies, Cooling Fans
Enclosure Management & Error Notification: Temperature failure, fan failure, power failure monitor and report. Audible alarm, status LEDs, remote paging
Battery Backup Module: Yes(option)
Model: SyneRAIDT-1600-3U3R SyneRAIDT-1600-UFCR
Host Type: Dual Ultra 160 SCSI channels Dual Loop 2Gb Fibre channels
Drive Types:
(No Western Digital)
All brands of Low-profile (1" high) IDE UDMA/100/133 drives with 5400, 7200rpm speed All brands of Low-profile (1" high) IDE UDMA/100/133 drives with 5400, 7200rpm speed
Maximum Cap/Enclosure >3.5TB >3.5TB

 

POWER REQUIREMENTS

Input Voltage: 100~240 VAC 46~63Hz
Power Supply Rating: 3 x 300 watt hot-swappable PSUs

 

CERTIFICATION COMPLIANCE

Emissions Requirements: FCC Class A
Safety Requirements: UL1950, CSA #950, TUV/EN60950
CE Compliance (EMC): 89/336/EEC EMC Directive

 

PHYSICAL CHARACTERISTICS RACKMOUNT

Width: 17.5" (445 mm)
Length: 22.87" (581 mm)
Height: 5.12" (131 mm) (3U)
Weight: 55.2 lbs.(25Kg) w/o drives
Environment: Ambient Temperature---- Operating: 5 C to 40 C; --- Non-operating/Storage: - 40 C to 70 C Relative humidity---- Non-operating: 95% non-condensing